LAK1: 2850 Interstate Drive, Lakeland, Florida
Colocation in Lakeland – LAK1 Data Center
Sitting at the highest point in Florida, LAK1 is one of the safest data centers in the state. LAK1’s advantages center on disaster recovery and colocation services, state-of-the-art security, redundant power systems, and a robust fiber network optimized for performance and speed.
Ideal Central Florida Data Center at Geographic High Point
Cologix’s state-of-the-art Lakeland data center is centrally located between Tampa & Orlando at an elevation of approximately 20 stories above sea level, offering disaster recovery & colocation services. Lakeland’s proximity to major market centers makes it a natural Central Florida colocation location for enterprises in Orlando, Miami and Tampa that need primary or secondary IT sites.
LAK1: Technical Specs
LOCATION
Located on Interstate 4 in the middle of Florida’s High Tech Corridor
Centrally located 32 miles from Tampa & 54 miles from Orlando
Approximately 20 stories, or 197 feet, above sea level
FACILITY
105K+ SQF disaster recovery & colocation facility
Custom cages & cabinets
Hardened, Category 5 hurricane-rated building; data center is a building within the building shell
Amenities include conference rooms, fitness area, theater, lounge area, staging & breakdown areas, loading docks, showers & offices for disaster recovery or everyday use
Seismic zone 0 & outside of floodplain
POWER
Medium & high-density load designs
Diverse power entrances, multiple generators, redundant uninterruptible power systems (UPS, & modular/redundant automatic transfer switches (ATSs)
Rapid power installation via unique bus distribution
Separate city power redundancy
Dual power feeds & 2 separate substations
COOLING
Chilled water cooling system
N+1 perimeter CRACs located off data center floor
SECURITY
24/7 on-site securitySecured entrance & exit procedures with multi-factored authentication & access control throughout
Mantraps, biometric authentication & customizable cabinet locking options
Video surveillance (interior & exterior) retained for 90+ days
Customized security available
FIRE PROTECTION
Safe air sampling smke detection (mechanical areas)
Dry pipe 4 stage system, FM200 fire suppression
NETWORK
Multiple carriers available in Cologix’s Meet-Me-Room
Network neutral data center
Mandatory dual fiber entrance (greater than 500 feet apart)
SUPPORT
24/7 direct access to geographically redundant Cologix Live Support
Access to self-service online customer care portal
All environmental & power monitored 24/7 via Cologix Command DCIM
Customer alerts when nearing power capacity to ensure business continuity
COMPLIANCE
SOC 1, SOC 2, HIPAA, and PCI-DSS compliant
All Lakeland Data Center Locations
LAK1:
2850 Interstate Drive, Lakeland, Florida
Ideal Central Florida Data Center at Geographic High Point
Read more